TECHNICAL INFORMATION
Director of Operations Melissa Hill (619) 440-0372
Technical Director John Ingersoll (619) 440-0343
Box Office (619) 440-2277
Box Office hours are Monday - Friday 9am - 5pm.
The House features continental seating with 1098 permanent seats in 27 raked rows of approximately 50 seats each. There are NO center aisles. There is space to accommodate 12 wheelchairs. Orchestra pit available upon advance notice.
Permanent Seating 1098
Wheelchair Seating 12
Orchestra Seating 32
TOTAL 1142
Artist Accommodations
1 Green Room (not to be used as a dressing room)
1 Star Dressing Room at stage level with restroom and shower (for adult use only.)
2 Chorus Dressing Rooms on the 2nd floor with restroom and showers.
Additional dressing areas are available by advance request only.
Load In
The stage door and loading dock driveway are located on the East side of the building on W.D. Hall Drive. The dock is wide enough to accommodate two semi trailers. The dock door entrance is located on the upstage right hand side of the stage. The dock height from driveway is 3'4" and the loading dock door is 8'w x 11'h.
General: Stage is a Tempered Masonite floor, painted black
Dimensions: Plaster line to Back Edge of Stage 40'
Apron to Back Edge of Stage 46'
Front of Raised Pit to Back Edge of Stage 56'
Please note: If Pit is used unseated, 32 seats are killed.
Stage Width 70'
Proscenium Opening
Curtain Line to Apron 6'
Curtain Line to Lift Apron 16'
Stage Right Area (concrete floor) 40' x 16'5"
Stage Left Area (concrete floor) 40' x 18'10"
Proscenium Height 26'
Height to Grid 40'
NOTE: Due to storage of Non-usable orchestra shell ceiling, maximum usable stage height is 19'6". House Floor to Stage
Pit Lift: Is electric and cannot be moved with riders
Has 3 operating positions - stage level, house level, and pit level
At pit position, can accommodate 45 musicians
Single purchase counterweight system is Stage Left at stage level
Uses an underslung fly system, therefore, blocks cannot be moved
The Main Drape is an Austrian Curtain that is electrically controlled at Stage Right and takes approximately 20 seconds to raise and to lower.
Main Drape Purple velour 71' x 28'
Borders Black velour, 3 60' x 10'
Legs Black velour, 3 pair 30' x 27'
Travelers Black velour, 2 72'x 27'
Cyclorama White Leno Filled-Scrim 60' x 30'
|
LIGHTING EQUIPMENT
ORCHESTRA SHELL
|
Control: ETC Obsession II 1500 (software version 4.4.2)
Dimmers:
Circuits: 20a/120v New Style Twist Lock
Fixtures: 30 36º ETC Source 4 Ellipsoidals
30 26º ETC Source 4 Ellipsoidals
20 19º ETC Source 4 Ellipsoidals (deadhung in AP)
10 ETC Source 4 15/30 Zooms
40 ETC Source 4 PARnels
40 ETC Source 4 PARs
8 Quartzcolor Iris 4
Followspots: 2 Stong HMI 575 (Metal Halide)
2 Strong Truss Trouper 1.2
Company Switch/Supplemental Power is located Down Stage Right, 400 amp/3-phase
NOTE: The ante-proscenium lighting positions are dead hung. There are permanently mounted fixtures for front lighting. ECPAC does not have a catwalk system and no one is allowed in the AP position. Prior arrangement must be made with Technical Director to focus this area.
The standard Lighting consists of:
21 cting areas with warm/cool front light and neutral-colored back lighting.
4 Neutral-colored stage washes (this includes one far upstage wash that is only usable if the cyclorama is not to be utilized).
Down-, mid-, and up-stage high side lights with Forerunner color scrollers.
1 down-stage right podium special.
1 down-stage center special.
*Contact Technical Director for current inventory, light plot, and stage diagrams.
|